RPP-E Base Bolts

RPP-E constitutes 2 to 4 headed high quality reinforcement bars which are factory welded to a threaded high-strength steel stud. There are two main anchor types: long anchors (type P) and short anchors (type L). RPP-E-P the long type ribbed bar bolts are suitable as overlapping bolts in precast columns and as base bolts.
These bolts are suitable for anchoring in large area components such as foundations or walls with sufficiently large edge distances.
It is available in Hot Dip Galvanized finish.

Approvals

  • Finland: 5B EC2 24 M1 / 5B EC2 15 M2
  • Russia: РОСС ЕЕ. АГ99.Н03197
  • Sweden / Norway: EN 1090

Dimensions of RPP-E Base Bolt

  Thread Bar Washer RPP-E-P RPP-E-L  
Base Bolt Size l-Thread

(mm)
Net Tensile
Area
(mm2)
n/D


Du

(mm)
Da/t

(mm)
L

(mm)
Weight

(kg)
L

(mm)
Weight

(kg)
color
RPP-E M30 30 190 561 2/25 55 65/8 1705 14.6 670 7.0
RPP-E M36 36 190 817 4/20 46 80/8 1370 17.8 740 8.6
RPP-E M39 39 200 976 3/25 55 90/10 1710 21.1 880 11.0
RPP-E M45 45 220 1306 4/25 55 100/10 1720 30.0 980 15.9
RPP-E M52 52 250 1758 4/32 70 100/12 1860 49.6 1140 30.0
RPP-E M60 60 310 2362 4/32 70 115/12 2390 63.8 1330 36.4
RPP-E-L
Dimensions of RPP-E Base Bolt
RPP-E-P
Dimensions of RPP-E Base Bolt

Resistances of the RPP-E

Base Tension Shear Net tensile area Lever
arm

Base Bolt

NRd
(kN)
VRd
(kN)
a
(mm2)
I
(mm)
RPP-E M30 299.2 34.5 561 83
RPP-E M36 435.7 52.6 817 96
RPP-E M39 520.5 61.4 976 108
RPP-E M45 696.5 88.6 1306 115
RPP-E M52 937.6 124.1 1758 129
RPP-E M60 1259.7 174.6 2362 142
NRd = nominal design tension resistance
VRd = nominal design shear resistance
e1 = base grout thickness + 0,5 x base plate thickness
a3 = 0,5 x d0
For further details related to resistances, please refer to our technical manual.

Resistances of the RPP Concrete grade C25/30

RPP-E Base Bolts Materials and Standards

Ordering Code Ribbed Bars Standards Threaded Bars Standard

RPP-E-L  
B500B SFS 1300
EN 10080 (SFS 1300)
(BSt500S DIN 488) (K500C-T SS 212540) (B500NC NS 3576-3)
High Strength
Steel Bars
fyk≥700MPa; fuk≥800MPa;
fuk/fyk≥1.08; εuk≥5%
Nuts Standard Washers Standard
Grade 10 dimensions EN 20899-2, EN ISO 898-2
EN-ISO 4032
S355J2 EN 10025
  Ribbed Bars Standards Threaded Bars Standard

RPP-E-P  
B500B SFS 1300
EN 10080 (SFS 1300)
(BSt500S DIN 488) (K500C-T SS 212540) (B500NC NS 3576-3)
High Strength
Steel Bars

fyk≥700MPa; fuk≥800MPa;
fuk/fyk≥1.08; εuk≥5%
Nuts Standard Washers Standard
Grade 10 dimensions EN 20899-2, EN ISO 898-2
EN-ISO 4032
S355J2 EN 10025